The ignition unit was flashing code 7 Flame Rod Shorted. I removed the igniter/pilot assembly and found a bridge of carbon across the electrical portion of the ignitor. I cleaned the ignitor and re-installed the assembly and everything worked fine, for 2 days. Same problem. I removed the assembly again but this time I also took apart the pilot.. Flame rod shorted to ground: Flame rod shorted to ground: Shorted or mis-wired flame rode wiring. Defective flame rod. Delta T inlet/outlet high: Temperature rise between supply and return is too high. Inadequate boiler water flow. Verify that pump is operating and that pump and piping are sized per Section VI of this manual. Return temp higher.

Auburn CS13039, FRS44 Flame Rod Auburn, Stromquist & Company
Auburn CS13039, FRS44 Flame Rod Auburn, Stromquist & Company
How does the gas furnace flame rod work. YouTube
How does the gas furnace flame rod work. YouTube
STANDARS IGNITORS & FLAME RODS WESTWOOD
STANDARS IGNITORS & FLAME RODS WESTWOOD
Why Flame Rod Failures Happen and How To Prevent Them
Why Flame Rod Failures Happen and How To Prevent Them
How Does A Flame Sensor Rod Work
How Does A Flame Sensor Rod Work
How to service the 80 gas furnace, flame rod checks.
How to service the 80 gas furnace, flame rod checks.
Honeywell Maxon 27731, Maxon Flame Rod 10.8in, Stromquist & Company
Honeywell Maxon 27731, Maxon Flame Rod 10.8in, Stromquist & Company
GordonPiatt Flame Rod 45/8
GordonPiatt Flame Rod 45/8" Nose Gordon Piatt
Auburn CS13044, FRS3 Auburn Flame Rod (27634), Stromquist & Company
Auburn CS13044, FRS3 Auburn Flame Rod (27634), Stromquist & Company
"Crown CA434 Replacement Flame Rod For Auburn FRS46"
FIREYE Flame Rod 18
FIREYE Flame Rod 18", Fits Brand Fireye 116D7669ND11000K6 Grainger
AO Smith 100110701 K,FLAME ROD Tools & Home Improvement
AO Smith 100110701 K,FLAME ROD Tools & Home Improvement
VELOCITY 433030 (10588001) FLAME ROD KIT PHNTM Climatedoctors
VELOCITY 433030 (10588001) FLAME ROD KIT PHNTM Climatedoctors
microcontroller Flame sensing using flame rod and short circuit
microcontroller Flame sensing using flame rod and short circuit
Flame Rod International Thermal Systems
Flame Rod International Thermal Systems
Flame Rod Shorted LED code Community Forums
Flame Rod Shorted LED code Community Forums
100110701 AO Smith 100110701 Flame Rod
100110701 AO Smith 100110701 Flame Rod
Auburn FRS412 AUBURN FLAME ROD 1/4
Auburn FRS412 AUBURN FLAME ROD 1/4" NPT 12" at Controls
Flame rod GFR3 WIKA Australia
Flame rod GFR3 WIKA Australia
Flame Rod Maxon 18117 Anatol Equipment Manufacturing Co.
Flame Rod Maxon 18117 Anatol Equipment Manufacturing Co.
FULTON FLAME ROD (FN220020) Parts 4 Cleaner
FULTON FLAME ROD (FN220020) Parts 4 Cleaner
Kanthal WFR212K Flame Rod Industrial & Scientific
Kanthal WFR212K Flame Rod Industrial & Scientific
Honeywell Maxon 27729 Flame Rod for OVENPAK 400 Series Burners
Honeywell Maxon 27729 Flame Rod for OVENPAK 400 Series Burners
Replacing the flame rod YouTube
Replacing the flame rod YouTube
RTG20164H Rheem RTG20164H Flame Rod, RTG20164H
RTG20164H Rheem RTG20164H Flame Rod, RTG20164H
High Quality RPFE Flame Rod Burner Flame Lonization Rod Flame
High Quality RPFE Flame Rod Burner Flame Lonization Rod Flame
Rinnai 205000068 Flame Rod, Ex38C
Rinnai 205000068 Flame Rod, Ex38C
Auburn Flame Rods E.S. Gallagher
Auburn Flame Rods E.S. Gallagher
AUBURN MANUFACTURING Flame Rod, 6
AUBURN MANUFACTURING Flame Rod, 6", 1/4" MTG, Fits Brand Auburn
101738B FLAME ROD C7005A B The Master Group
101738B FLAME ROD C7005A B The Master Group

Flame rods are positioned so that one end end of the flame rod is in direct contact with the burner flame and the other end is connected to the furnace ignition board. Once the board sends 24vac to the gas valve to open, it monitors current flow on the flame sensing rod.. Flame sensors fail when: They short out due to a cracked insulator.. Clean the rod with a scotch brite pad and use the ohm setting to check the rod length to the other end, should be less than 1 ohm with no cracks or tracking to ceramic. Then with meter in series flame microamps should be 2 or more. If less than 2 usually flame size or ground although sometimes internal problem in control.